井点布置的基本原则
(1)常用轻型井点的成孔孔径应根据土质条件和成孔深度确定,孔径常用Φ250~300mm,间距1.2~2.0m,冲孔深度应超过滤管管底0.5m。
1) commonly used light well point into a hole diameter should be determined according to soil conditions and the hole depth, aperture Φ commonly used 250 ~ 300 mm, spacing of 1.2 ~ 2.0 m, should exceed the bottom of the filter tubes punching depth of 0.5 m.
(2)井点成孔应垂直,井点管滤头宜设置在透水性较好的土层中,必要时可采取扩大井点滤层等措施。国产压力变送器推动市政管道井排水自动化使用推荐
Well point drilling should be vertical, well point pipe filter head should be set in the soil layer with good permeability, when necessary, measures such as expanding well point filter layer can be taken.
(3)放坡开挖的基坑,井点管距坑边不小于1.0m,机房距坑边不小于1.5m。
For the foundation pit with slope excavation, the distance between well point pipe and pit edge shall be no less than 1.0m, and the distance between machine room and pit edge shall be no less than 1.5m.
(4)井点降水设备的排水口应与坑边保持一定距离,防止排出的水回渗,流入坑内。
The dewatering port of the well point dewatering equipment should keep a certain distance from the pit edge to prevent the discharged water from infiltrating back into the pit.
(5)拔除井管后的孔洞,应立即用砂土填实。对于穿过不进水层进人承压含水层的进管,拔除后应用黏土球填塞封死,杜绝井管位置发生管涌。
轻型井点排水
Sand should be used to fill the hole immediately after the well pipe is removed. For the pipe entering the confined aquifer through the waterless layer, clay ball should be used to seal the pipe after pulling out, so as to prevent piping from happening in the position of the well pipe.
Light well point drainage
(1)集水总管、滤管和泵的位置及标高应正确,井点系统各部件均应安装严密,防止
漏气。连接集水总管与井点管的弯联管宜采用软管。
(2)按封闭方法布置单套井点设备时,集水总管宜在抽水机组的对面断开。采用多套
井点设备时,各套井点设备的集水总管之间宜装设阀门隔开。
(3)井点管的沉设可按现场条件及土层情况选用:
① 直接利用井点管水冲下沉。
② 用冲水管冲孔(亦可同时用压缩空气或使用加重钻杆辅助冲孔)后,沉设井点管。
③ 套管式冲枪水冲法或振动水冲法成孔后。沉设井点管。
(4)冲孔孔径不大于300mm,深度应比滤管底深0.5m以上,管距一般为0.8~1.6m。
(5)每根井点管沉设后检验渗水性能:井点管与孔壁填砂滤料时,管口应有泥浆水冒出。向管内灌水,能很快下渗,方为合格。国产压力变送器推动市政管道井排水自动化使用推荐
Test the water seepage performance of each well point pipe after sinking: when the well point pipe and the hole wall are filled with sand filter material, the mouth of the pipe should be out of mud water. To the tube irrigation water, can soon infiltration, qualified.
(6)井点系统安装完毕,必须及时试抽,并全面检查管路接头质量、井点出水状况和抽水机机械运转情况等。如发现漏气和“死井”应立即处理。检查合格后,井点孔口到地面5~l.0m的深度范围内应用粘性土填塞。
When the wellpoint system is installed, it is necessary to test the pumping in time, and comprehensively check the quality of the pipeline connection, the status of the pumping water and the mechanical operation of the pumping machine. If leakage and "dead well" are found, they should be dealt with immediately. After passing the inspection, clay soil filling should be applied to the depth range of 5~l.0m from the wellpoint orifice to the surface.
(7)轻型井点按抽水机组类型分为:干式真空泵井点、射流泵井点和隔膜泵井点。
The light well point can be divided into dry vacuum pump well point, jet pump well point and diaphragm pump well point according to the type of pumping unit.
① 干式真空泵井点,可根据含水层渗透系数大小选用相应型号的真空泵和水泵。
② 射流泵井点和隔膜泵井点。适用于粉砂、黏质粉土等渗透系数较小的土层中的降水。
③ 干式真空泵井点的水泵与排水管连接处,宜装置止回阀。气水分离箱与总管连接的管口应高于水泵的叶轮轴线。
市政过程中对工艺参数进行检测、显示、记录或控制的变送器厂家。 工艺生产过程的检测是了解和控制工业生产的基本手段,只有在任何时刻都能准确地了解工艺过程的全貌,并进行控制,才能保证生产过程顺利,并以高的生产率、小的消耗生产出合格的产品
华恒变送器厂家研发出传感器和智能电路板两项核心技术,不仅所有产品的核心部件技术全部掌握,工业自动变送器厂家的精确度也在不断提高,由0.2级提高到0.1级。还可通过对所掌握核心技术进行延伸,变形出测流量、测温度的其他产品。
压力(表压)/绝对压力变送器,是以大气压/真空为参考端测量的压强信号,只有一个端口和工艺管道链接。金属电容式压力(表压)/绝对压力变送器工作原理,当压力通过隔离膜片和导压介质间作用在不同厚度的金属测量膜片弹性测量元件)的表面,使膜片产生微小的变形,
最大变形不超过0.1mm,高精度测量电路将这个微小的形变转换层一个与压差信号成线性关系的电压信号,进故宫线性化,温度补偿,然后采用专用芯片将这个电压信号转换为工业标准的4-20ma电流信号或1-5V电压信号。国产压力变送器推动市政管道井排水自动化使用推荐
由金属电容式压力传感器的高灵敏度和测量膜片检测电路采用的高精度集成电路,内部包含
线性及温度补偿电路,所以整个变送器都可以做到高精度和稳定性。
金属电容式极高的抗过载性能和在微压测量方面的优异表现,更是个中国复杂的工业环境现场的必选产品。
凡是在两个平面周边使用螺栓连接同时封闭的连接零件,一般都称为“法兰”,
华恒变送器厂家凭借自身拥有的传感器和智能电路板核心技术,可以根据客户要求,低成本对核心技术进行延伸变形,实现个性化产品定制。主要产品有SMART(斯玛特)系列压力变送器、多参数变送器、流量器、温度传感器和物位(液位变送器厂家,为我国电力、石油、化工、冶金、水泥、矿业等行业提供了高性能价格比的工业自动变送器厂家产品.